- +1 (212)-695-1962
- info@elementskit.com
- 463 7th Ave, NY 10018, USA
LP Flare Package
32” x 4 m LP Air Assist Flare Tip c/w 21 m OH Guy Supported Stack
3 Pilot / Ignitor (HEI-HV)
Pilot Instrumentation c/w Automatic / Manual FFG Backup, Manual LPG Backup Instrumentation
ICP (Eex’d’), ICP / Instrumentation Skid
API 560 Air Assist Blower Skid, VFD
2 IR Monitors
AP Air Assist Flare Package
106.3 m OH Guy Supported Stack c/w 20” x 3.7 m AP Air Assist Flare Tip.
L&P, Retractable Davit
Pilot / Ignitor (HEI-HV) / SETC, HT
ICP (Eex’d’)
Pilot Instrumentation c/w Propane FGBU & ICP / Instrumentation Skid
Non API 560 Air Assist Blower Skid
AP & HP Flare Packages
45 m O/H Flare c/w 36” x 3.7 m AP Air Assist Flare
45 m O/H Flare c/w 12” x 3.7 m HP Utility Flare Tip
L&P, Pilot / Ignitor (HEI-HV) / DETC, HT
ICP (Eex’d’), Pilot Instrumentation c/w Automatic / Manual FFG Backup,
ICP / Instrumentation Skid, API 560 Air Assist Blower Skid
(2) IR Monitors and (3) ACWL / Control Panel.
HP and AG Flare Tip Packages
3 m OH Guy Supported Stack c/w 10” x 3.7 m LP Utility Flare Tip
Retractable Pilot / Ignitor (HEI-HV) / DETC
ICP (Eex’d’), Pilot Instrumentation, ICP / Instrumentation Skid
LPG Skid for accommodating 12 LPG Cylinders.
LP Utility Flare Package
106.3 m OH Guy Supported Stack c/w 20” x 3.7 m AP Air Assist Flare Tip.
L&P, Retractable Davit
Pilot / Ignitor (HEI-HV) / SETC, HT
ICP (Eex’d’)
Pilot Instrumentation c/w Propane FGBU & ICP / Instrumentation Skid
Non API 560 Air Assist Blower Skid
Offshore Utility Flare Tips
43 m O/H Flare Tower c/w 2 Nos. of 10” Tip FGV-VS Insert
Pilot / Ignitor (HEI-HV) l FFG / SETC,
Pilot / FFG Instrumentation c/w Manual FFG, Automatic / Manual ICP
ICP / Instrumentation Skid.
HP Flare Packages with Demountable Derrick System
Common Demountable Flare Derrick (50 m O/H) c/w (2) 20” x 3.7m long HP Flare Tip
Platforms & Ladders
Electronic / FFG Pilot Flare Ignition System (Auto HEI / Manual FFG)
LPG Back Up and Retractable Aircraft Warning Light System
LP Flare Package & Burnpit Flare Tip
46 m OH Guy Supported Stack c/w 40” x 30” X 4 m LP Air Assist Flare Tip
3 Pilot / Ignitor (HEI-HV) / DETC, HTHV
2 X 100% Blowers.
8” X 4 m Burnpit Flare Tip c/w 2 Pilot / Ignitor
2 AUTO/Manual FGBU Instrumentation as Backup and 2 ICP / Instrumentation Skids
Pilot Instrumentation c/w AUTO / Manual Pilot Backup
Thermal Oxidizer
One Vertical Free Standing Incinerator overall height of 25m
Combustion Chamber and Stack of 2.4m OD x 22.0m lg
One Main Fuel Gas Burner (316SS) c/w Pilot / Ignitor System
One Burner Management System (BMS) c/w ICP.
One Main and Pilot Fuel Gas Instrumentation Skid
Two x 100% Purge / Combustion Air Blower